EMG/NCV/EP 5000Q

EMG 5000Q

NegarAndishgan Ltd. EMG/NCV/EP 5000Q Manufacturing  is a full featured diagnostic EMG system with a low noise high performance amplifier and state-of-the-art software features. This system can be configured for 2 channels (configuring for 4 channels is optional).

 In following, there are the list of the tests which can be taken:

  • Needle EMG
  • Sensory NCV
  • Motor NCV
  • F Wave
  • H reflex
  • RNS (Repetitive Nerve Stimulation)
  • Blink Reflex
  • Visual Evoked Potential
  • Auditory Evoked Potential
  • Somatosensory Evoked Potential

PW4

Protocol Wizard:

  • This EMG System is a powerful tool for defining the new tests, designing and customizing your system in your own way.
  • Name of nerves, muscles, number of signal traces, method of calculation, shape of result table, final report and many other options can be defined by protocol wizard.
  • Microsoft word report generator can help you to generate your report in less than a minute.
  • Graphical directory for muscle and nerve electrode placement can give you useful recommendations.

PW1

  • There are many kind of applicable functions such as:
    • Left and Right comparison
    • Super imposer
    • Peak detector
    • Needle Video and Audio reviewer
    • Signal annotation to help you get more precise results
  • MYSQL Server guarantees the integrity of data management which can be accessed through the network.
  • ASCII data extraction + Real-time access to the recorded data (e.g. by using MATLAB).

 

Technical Specifications:

  • Accuracy: Time measurement error: less than 5%; Amplitude measurement error: less than 5%
  • 2, 4 Channel EMG and EMG/EP Systems
  • Input Impedance: > 1000MΩ, < 30pF; CMRR > 120dB; Noise < 1μV r.m.s
  • Low Cut ( -6dB/octave) 0.1, 1, 3, 10,, 30,100, 200, 300, 400, 500, 1000, 2000Hz
  • High Cut (-12dB/Octave) 40, 50, 60, 80, 100, 200, 300,400, 500 Hz; 1, 2, 3, 10, 20 KHz
  • Notch Filter 50Hz/60 Hz Selectable
  • A-D Conversion 12 Bit ADC
  • Sweep Duration 1ms to 1s per channel
  • Average Double buffer averaging with choice of display modes
  • Display Customer option; Display Sensitivity 0.2μV to 30mV/div

Power Requirements: Input 100-220 volts 50Hz/60HZ

           Approx. 500VA max (dependant on configuration)

Contact Information

To order devices:
+98 21 76250713-16 (Ext. 1)
+98 912 0391224
+98 912 2543035

To buy accessories:
+98 21 76250713-16 (Ext. 2)
+98 902 2543221

Technical support:
+98 21 76250713-16 (Ext. 3)
+98 912 0763280